SERIES U-755 FS
The U-755 FS range Float Sensor has been designed using Universal Switch Gear Control’s proven reliability in combination with the latest Technology. U-755 FS cable suspended float sensor are designed to provide the control signals for a differential pump control system.
These floating sensors are suitable for use in a variety of open tanks or vessels. The ABS cover float and the PVC cable make them ideal for most pump control applications. A number of float units can be used together to give multiple level switch points in one flanged holder. Each float can be easily assembled on site and the switch operating points are adjusted by altering the length of the cable.
APPLICATIONS:-
(i). Water
(ii). Waste Water
(iii). Sticky liquids
FEATURES:-
(i). Insensitive to suspended solids or viscosity: - No affection from suspended solids or viscosity of measured liquids due to large buoyancy.
(ii). Stable operation: - No affection from turbulence or rough flow as detection signals are not given until the float is inverted at the high or low points.
(iii). Flexible adaption to any environments: - Easy installation by just suspending the sensor. Control range is user adjustable. Multiple point versions are also available. Large and rugged terminal box for easy handling, with a cover requiring neither screws nor bolts.
(iv). High reliability: - Among high accuracy reed switches, only those that meet our original standards are used to ensure stable operation over the long service life.
OPERATIONAL DESCRIPTION:-
The U-755 FS range contains a hermetically sealed reed switch, a permanent magnet, and a movable weight. As the liquid level rises and falls, the movable magnetized weight slides up and down inside the float and acts upon an encapsulated reed switch. The float tumbles at its upper and lower limits. In this way the reed switch changes state at the upper limit and remains in this state until the lower limit is reached and it changes state again.
MODEL NUMBER & REFERENCES:-
|
|
|
|
|
|
|
|
|
SR. NO.
|
Model No.
|
Length
|
Max. Capacity
|
Max. Current
|
Max. Voltage
|
|
AC
|
DC
|
AC
|
DC
|
AC
|
DC
|
1
|
U- 755 FS / 5 /220V AC
|
5 m
|
50VA
|
50W
|
0.5A
|
0.5A
|
300V
|
300V
|
2
|
U- 755 FS / 3 /220V AC
|
3 m
|
50VA
|
50W
|
0.5A
|
0.5A
|
300V
|
300V
|